[802SEC] 802.15. Comments on PARs



Dear All,

 

802.15 SC Maintenance reviewed the PARs and CSDs and has 1 question / comment:

 

802.3dj PAR and CSD

 

802.3dj PAR states:

5.2.b Scope of the project: Define Ethernet MAC parameters for 1.6 Tb/s. Define physical layer

specifications, and management parameters for the transfer of Ethernet format frames at 800 Gb/s and

1.6 Tb/s over copper, multi-mode fiber, and single-mode fiber physical medium dependent (PMD)

sublayers, based on greater than 100 Gb/s signaling technologies. Use this work to define derivative

physical layer specifications and management parameters for the transfer of Ethernet format frames at

200 Gb/s and 400 Gb/s.

 

802.3dj CSD states:

Distinct Identity

The proposed amendment will define derivative physical layer specifications

from those developed for 800 Gb/s and 1.6 Tb/s Ethernet to address copper,

multi-mode fiber, and single-mode fiber specifications, based on a reduced

number of physical lanes, for 200 Gb/s and 400 Gb/s Ethernet.

 

Economic Feasibility

In consideration of installation costs, the project is expected to use proven and familiar media, including electrical backplanes, twin-axial copper cables, multi-mode optical fiber cabling, and single-mode optical fiber cabling.

 

Under “Economic Feasibility”, multi-mode optical fiber cabling is struck out.  Is this intentional and, if so, why?

 